Visible Fix Wall panel

//Visible Fix Wall panel
Visible Fix Wall panel 2018-01-06T15:24:54+00:00

Project Description

Maximum allowable uniformly distributed load (Kg/m2)

T(mm) / S(mm) 150 200 250 300 350 400 450 500 550 600
30 186 137 100
40 251 186 147 103 62
50  316 234 186 153 101 65
80 302 250 213 178 122 86 62
T(mm) / S(mm) 150 200 250 300 350 400 450 500 550 600
30 186 108 66
40 251 186 147 122 74
50  316 234 186 153 121 77
80 302 250 213 185 146 103 74

– The allowable loads (L) are specified in [Kg/m2] and the deflection at midpoint are not
exceeding 1/100 of span lenght.
– The tables don’t replace the structural analysis required for execution of the
constructional work and have been determined according to EN-14509
– Review with the Egyptian Code should be done by the designers.

Item Specs
Core PUR – PIR
Thickness (mm) 30 – 40 – 50 – 80
Width (mm) 1000 – 1150
Maximum Lenght (mm) 14000 (depending on transportation conditions)
External Facing Thickness (mm) (0.4 – 0.5 – 0.7)
Internal Facing Thickness (mm) (0.3 – 0.4 – 0.5 – 0.7)
Zinc Coating G 60 – 180 gm/m2
Front Face Coats (Microns) 25 microns nominal (20 microns of polyester paint+5 microns of primer).
Back Face Coats 7 microns of primer
Reaction to Fire PIR : – BS2d0 as per EN13501-1
– B1 as per DIN 4102
– Class 1 as per BS476
– El 30 for thickness 80-100 mm
Reaction to Fire PUR : BS3d0 as per EN14509 – EN 13501
Thickness (mm) U Value (w/m2k) Weight 0.5+0.5 (kg\m2)
30 0.68 9.60
40 0.51 10.00
50 0.41 10.40
80 0.26 11.60